Overhang · horizontal blades 1 · single 2 · equal divisions 3 · equal divisions 4 · equal divisions
Fin · equal-width bays 1 · single 2 · equal divisions 3 · equal divisions 4 · equal divisions
Horizontal · extra at each side Additional extension at each side, 0–20 ft. May extend beyond the wall edges. Added after the original joint and open-side extension rules; panel depth and rotation stay unchanged.
Vertical · extra above top Additional upward extension, 0–20 ft. The bottom stays at the sill; the top may extend above the roof. Added after the original joint rule; panel depth and rotation stay unchanged.
Horizontal blades divide the window height equally. Each blade sits at the top of its interval; unrotated blade length = (window height / divisions) / tan(base profile angle). Vertical fins divide the width into equal bays; unrotated blade length on each enabled side = (window width / divisions / 2) / tan(base HSA cutoff), where HSA cutoff = 90° − the corresponding vertical shading angle. A side with angle 0° has no fins. With one side enabled, N bays use N fins; with both enabled, shared interior fins are merged to the greater required depth, giving N + 1 physical fins. Angle settings remain shared across views. Enable Geometry mask to edit this system; the geometry, shadows and calculated mask update across all views. Every horizontal blade extends sideways in its own plane to meet tilted fins, including the middle and lowest blades. On a side without a fin, the rear-edge extension is half the divided window height: window height / horizontal divisions / 2. Fin top edges follow the top overhang plane, extending upward or being trimmed for a downward slope. Fin depth and overhang profile lengths remain the design inputs; actual fin top heights and horizontal blade widths can vary after joining. If a downward top plane reaches the sill, the fin is clipped there. Entering Shading design automatically enables the shading mask. With no physical fins, the reference marker remains at the whole-window sill center regardless of the saved fin divisions. With fins, the reference marker sits at the sill midpoint of a central equal-width bay: the central bay for odd counts, or the left central bay for even counts, viewed from inside looking out. Select 1 and rotation 0° to restore the original single-panel arrangement.
Overhang · VSA Left fin · HSA Right fin · HSAOverhang shows one purple VSA arc and the shading mask reference: the angle is measured from the outward horizontal line at the sill reference to the lowest blade’s outer edge in the vertical section normal to the façade. For an unrotated horizontal blade, tan(VSA) = H / D, where H is the vertical separation from the reference to that blade and D is its outward depth. Dimensions remain in the shading statistics. Fin guides show only the actual left or right HSA and a shared shading mask reference. Purple arcs show the measured angle; blue dashed lines mark the outward façade normal, and dark sightlines connect the reference to the physical fin edge. Design-angle duplicates and dimension labels are omitted from the model. Overhang VSA is measured in a vertical section from the outward horizontal normal to the edge sightline. Fin HSA is measured in plan from the outward façade normal to the fin-tip sightline. Each checkbox independently shows its annotation; all are off by default. The existing side shading sliders measure the complementary angle V from the wall direction: HSA = 90° − V before rotation. For example, a 30° side slider produces a 60° HSA label. This annotation convention does not resize the model. Base sizing and the geometry mask use the same sill midpoint of the selected bay. For bay width W and vertical shading angle V measured from the wall direction, fin depth D = (W / 2) tan(V), equivalently (W / 2) / tan(HSA), with HSA = 90° − V. At zero rotation, an isolated fin has the requested V at this point. A finite or rotated assembly can have several mask boundaries; one edge angle does not describe the complete mask. Left and right follow the window labels, viewed outward from inside. Labels are projected 3D angles, not angles measured on the screen.
Overhang · PF Left fin · PF Right fin · PFProjection factor PF = A / B, dimensionless. PF checkboxes show compact A and B dimension lines on the model, not angle arcs. Overhang A runs through the middle of the selected bay on the horizontal blade; B runs vertically from sill to blade at the window plane. Fin A runs outward at window mid-height, and B spans the full bay width along the window plane. Numeric A, B and all three PF results remain visible in Shading statistics independently of these checkboxes. VSA and HSA controls keep their separate angle arcs. A is the outward projection perpendicular to the window plane. For an overhang, B is the vertical distance from the sill to the underside of the horizontal panel. For a sidefin, B is the full distance from its wall attachment to the opposite window jamb, not the distance to the sill midpoint used by HSA. Therefore fin PF is not simply cot(HSA): for a perpendicular fin at the edge of a symmetric bay, PF = 0.5 × cot(HSA). Left/right are viewed from inside looking out. With divisions, the display explicitly reports a local cell PF: the lowest horizontal interval or full selected-bay width. This cell interpretation extends the paper’s single-window definition; it is not a whole-system performance rating. Shared interior fins use their actual modeled depth, which can be the larger adjacent depth. For rotated panels, PF statistics show N/A and the PF dimension lines are hidden: the simple definition is not applied to tilted geometry. Special shading has no single PF and these guides remain disabled. Lateral overhang extensions and fin height extensions do not change these ratios. PF is not shaded-area fraction, shading coefficient or energy savings. Source: Kolderup and Eley, Evaluating the Impact of Overhangs and Sidefins (ACEEE, 1992), Figures 1–2. https://www.aceee.org/wp-content/uploads/proceedings-1980-2020/1992/SS92_Panel1_Paper20.pdf
Multiple shadowsCompare actual finite-panel shadows in two modes: Three times uses 09:00, 12:00 and 15:00 apparent solar time on the selected date. Seasons uses the current Solar time for summer solstice, equinoxes and winter solstice. Seasonal cases follow the existing idealized sun-path model: June 21 and December 21 are representative solstices; March and September equinox paths coincide and are represented by March 21. These are teaching dates, not year-specific astronomical event times. Summer/winter labels reverse in the Southern Hemisphere. Change the main Solar time control to update all seasonal cases together. Colored outlines and light fills show each time on the window and nearby façade. Click a colored time label in this panel to isolate its shadow and read its window-shaded percentage. All times / All seasons restores the three-case overlay. The selected label is highlighted. Percentages report the shaded fraction of the entire window, combining overlapping panel shadows once. Night and sun behind the façade are reported separately, without a percentage. A single selected case with sun behind the façade darkens the window and its wall without an on-model text notice. The façade itself receives no front-facing direct beam, so the shading panels have no separate shadow there; this does not indicate shading failure or the absence of diffuse skylight. Sun below horizon is a separate state. All-case overlays keep neutral façade colors and report these states in their individual labels. Wall colors are explanatory, not simulated illuminance. Color overlap is not cumulative hours or daylight illuminance. While comparing, the single-time ground shadow is hidden. The Shading statistics and right-side Solar position / Shadow readouts still describe the selected main date and time; use the colored comparison buttons for each comparison case’s window-shaded percentage. This comparison is available only in Shading design, follows location, date, façade and panel geometry, and does not change the selected date, main solar time or EPW statistics.
Compare Three times · selected date Seasons · current solar time
All three times 09:00 12:00 15:00 Summer solstice Equinoxes Winter solstice